欢迎进入北京龙盛门业有限公司网站
全国服务热线
13940183063
常见问题
「衡水堆积门」快速门SEJ编码器和机械限位开关
时间: 2019-06-29 18:20 浏览次数:
「衡水堆积门」SEJ快速门控制箱的限位调试【编码器和机械限位开关调试】


「衡水堆积门」SEJ快速门控制箱的限位调试【编码器和机械限位开关调试

Limit Debugging of SEJ Fast Gate Control Box of Hengshui Accumulation Gate [Debugging of Encoder and Mechanical Limit Switch]

 

编码器用于确定快速门的行程,设定快速门可以升到哪里,降到哪里,因此,也称做行程开关。


Encoder is used to determine the travel of the fast door, setting where the fast door can rise and fall, so it is also called the travel switch.


有多种分类,增量编码器,绝对值编码器,又有空心,实心之分。


There are many kinds of classification, incremental encoder, absolute encoder, and hollow, solid.


常用的编码器品牌有:SFT,SEJ等,编码器和机械限位装置同样可以控制快速门的行程,他们的调试方法,是根据您选择哪个品牌的控制器,常用的变频器品牌有:SEJ/SEW/SFT/三菱/海利普/士林等


Commonly used coder brands are: SFT, SEJ, etc. Encoder and mechanical limit device can also control the journey of the fast door. Their debugging method is based on which brand of controller you choose. Commonly used frequency converter brands are: SEJ/SEW/SFT/Mitsubishi/Helip/Shilin, etc.
 

快速门编码器M02-12A
 

(1)手动或者自动转换开关打到手动状态。


(1) The manual or automatic switch is switched to the manual state.



(2)
急停按下,同时按↑键和↓键3秒,变频器显示“STU0”,开始学习限位。


(2) Press the key and key at the same time for 3 seconds. The frequency converter displays "STU0" and starts learning limit.


(3)
急停拉起,同时按↑键和↓键,门调整到下限位。手/自动转换开光转到自动,再转回手动,变频器交替显示1000与“STU1”,(按↑键是增大,按↓键值减小,如反向,请对调EPAEPB接线),下限位的实际脉冲值可以查看说明书P542


(3) Pull up immediately, press_key and_key at the same time, and adjust the door to the lower limit. Hand/Auto Switch on to Auto, then back to Manual, the converter alternately displays 1000 and STU1, (press_key is increased, press_key value decreases, if reverse, please adjust EPA, EPB wiring). The actual pulse value of lower limit can be seen in the instruction P542.


(4)
再按↑键和↓键,门调整到上限位。手/自动转换开关转到自动,再转回手动,变频器交替显示目前编码器的值与“STU2”,上限位的实际脉冲值查看说明书P543.


(4) Press_key and_key again, and adjust the door to the upper limit. Hand/automatic switch to automatic, then back to manual, the converter alternately shows the current encoder value and "STU2", the upper limit of the actual pulse value see instructions P543.


(5)
在按↑键,门调整到超上限位,手/自动转换开关转到自动,再转回手动,记录目前编码器的值(此值大于上限位值),按↓键关门,EPB是机械限位开关的上限位;


(5) When pressing_key, the door is adjusted to exceed the upper limit, the hand/automatic switch is turned to automatic, and then back to manual, recording the value of the current encoder (this value is greater than the upper limit), closing the door by_key, EPB is the upper limit of the mechanical limit switch;

 

快速门机械限位



(4)通过机械限位开关行程的调节,可直接应用。


(4) It can be directly applied by adjusting the stroke of the mechanical limit switch.

 

Copyright © 北京龙盛门业有限公司 版权所有 辽ICP备:备案中···
全国服务电话:13940183063   售后服务:024-31081023
公司地址:北京市怀柔区宝山镇

百度地图 - 网站地图